Standard DC 0/1-10V control interface, Sink or Source <1mA 10V PWM dimming control, Infrared remote control Wide dimming range from 0% up to 100%, Dimming Over entire input voltage voltage
Protections
Short Circuit
Hiccup mode protection. Recovers automatic after fault condition is removed.
Over Voltage
<30% above the maxmum output voltage listed for the specific part number.Latch mode-unit needs to be power cycled to recover
Over Current
<15% above the maximum output current listed for the specific part number. The unit limits the current. Unit autorecovers after fault is removed
Over Temperature
Unit turns off when Tc>90℃.Shuts down-unit needs to be power cycled to recover
Ambient Temp Range
-20℃ to +60℃, 20-95% RH non-condensing
Max Case Temperature(Tc)
75℃ for Life & 85℃ for UL Safety
Environment & Approbation
Working Temperature
_30℃ ---+60℃ at Full load
Working Humidity
20% --- 90% RH non-condensing
Storage Temperature, Humidity
_40°C --- + 80°C, 10% --- 90% RH non-condensing
Vibration
10 - 500Hz, 2G 10min/1 cycle period for 60 minutes along each axis (X, Y, Z)